Certified Real Estate Inspections by Gregory Vishey, BSME, MSA, CRI.
Member SAE, NAHI, MIC-NAHI NAHI - NATIONAL ASSOCIATION OF
HOME INSPECTORS, INC. These Standards may not be reproduced
without written permission from the National Association of Home Inspectors,
Inc. © 2002 4248 Park Glen Road, Minneapolis, Minnesota 55416, (952)928-4641 TABLE OF CONTENTS 1. Purpose, Scope & General
Statements 2. General Limitations & Exclusions
3. Site 4. Foundations 5. Exterior 6. Roof Coverings, Flashings,
Gutters, Downspouts and Roof Ventilation. 7. Roof Structure, Attic & Insulation
8. Attached Garage(s)/Carport(s) 9. Electrical 10. Plumbing 11. Central Heating 12. Central Air Conditioning 13 Interior Glossary of Terms Code of Ethics STANDARDS OF PRACTICE 1. Purpose, Scope and General
Statements 1.1 The Standards of Practice (7/2003
Standards) provide the minimum standards of performance for a written report on
a residential home inspection performed by and for the exclusive use of members
of the National Association of Home Inspectors, Inc. (NAHI ™). 1.2 The Standards define and clarify
the purpose, conditions, limitations, exclusions, and certain terms relating to
an inspection. 1.3 The Standards describe those
items, components, and systems included in the scope of an inspection. 1.4 The Standards apply only to the
inspection of buildings with one (1) to four (4) dwelling units. 1.5 The Standards apply to a visual
inspection of the readily accessible areas of the included items, components,
and systems to determine if, at the time of the inspection, they are performing
their intended function without regard to life expectancy. 1.6 The purpose of the inspection is
to identify visible defects and/or conditions that, in the judgment of the
Inspector, adversely affect the function and/or integrity of the items,
components, and systems. 1.7 Inspections performed under the
Standards are basically visual and rely upon the opinion, judgment, and
experience of the Inspector, and are not intended to be technically exhaustive. 1.8 Inspections shall be performed in
a time period sufficient to allow compliance with the provisions of the
Standards, 1.9 Inspections performed under the
Standards shall not be construed as a compliance inspection of any code,
governmental regulation, or manufacturer's installation instructions or
procedures. In the event a law, statute, or ordinance prohibits a procedure
recommended in the Standards, the Inspector is relieved of the obligation to
adhere to the prohibited part of the Standards. 1.10 Inspections performed under the
Standards are not an expressed or implied warranty or a guarantee of the
adequacy, performance, or useful life of any item, component, or system in, on,
or about the inspected property. 1.11 Detached building(s) and
detached garage(s) located on the property will be inspected under these
Standards only if specifically listed in the inspection report. 1.12 The National Association of Home
Inspectors recommends that its members perform inspections in accordance with
these Standards, the Code of Ethics, and applicable law(s). The Standards are
not intended to limit members from performing "additional inspection services." 1.13 The inspector shall report on
any system and component included in these standards of practice which were
present at the time of the home inspection but were not inspected and provide
the reason they were not inspected. 2. General Limitations and
Exclusions 2.1 Inspections performed under the
Standards exclude any item(s) concealed or not readily accessible
to the Inspector. The Inspector is not required to move furniture, personal,
or stored items; lift floor coverings; cove attached wall, ceiling
coverings, or panels; or perform any test(s) or procedures(s) which could damage or
destroy the item(s) being evaluated. 2.2 The following are excluded and
not limited to: appliances, recreational facilities, alarms, intercoms, speaker
systems, radio controlled devices, security devices and lawn irrigation systems. 2.3 The determination of the presence
of or damage caused by termites or any other wood-damaging insects or organism
is excluded. 2.4 Also excluded from a standard
home inspection is the determination of the indoor air quality or sickness of
any building including, but not limited to, the presence or absence of all
manner of biological activity, such as molds, insects, birds, pets, mammals, and
other flora and fauna, and their consequent physical damage, toxicity, odors,
waste products, and noxiousness. 2.5 Use of special instruments or
testing devices, such as amp meters, pressure gauges, moisture meters, gas
detectors and similar equipment is not required. 2.6 The inspection is not required to
include information from any source concerning previous property, geological,
environmental or hazardous waste conditions, manufacturer recalls or conformance
of proper manufacturer's installation of any component or system, or information
contained in Consumer Protection Bulletin. The inspection is not required to
include information from any source concerning past or present violations of
codes, ordinances, or regulations. 2.7 The inspection and report are
opinions only, based upon visual observation of existing conditions of the
inspected property at the time of the inspection. THE REPORT IS NOT INTENDED TO
BE, OR TO BE CONSTRUED AS, A GUARANTEE, WARRANTY, OR ANY FORM OF INSURANCE. The
Inspector will not be responsible for any repairs or replacements with regard to
the property or the contents thereof. 2.8 Inspector not required to
determine property boundaries or encroachments. 2.9 The inspector is not required to
provide an inspection of any condominium common component, system or evaluate
condominium reserve accounts. 3. Site 3.1 Components for Inspection. 3.1.1 Building perimeter, land grade,
& water drainage directly adjacent to the foundation 3.1.2 Trees and vegetation that
adversely affect the structure. 3.1.3 Walks, grade, steps, driveways,
patios, retaining walls contiguous w/ structure. 3.2 Procedures for Inspection - The
Inspector will: 3.2.1 Describe the type of material
and inspect the condition of the driveways, walkways, grade steps, patios, and
other items contiguous with the inspected structure. 3.2.2 Observe the drainage, grading,
and vegetation for conditions that adversely affect the structure. 3.3 Limitations – The Inspector is
not required to: 3.3.1 Inspect fences or privacy
walls. 3.3.2 Evaluate the condition of
trees, shrubs, and or other vegetation. 3.3.3 Evaluate/determine soil or
geology, site engineering, or boundaries. 4. Foundations 4.1 Components for Inspection. 4.1.1 Foundation walls, first-floor
systems, other support and sub-structure components, stairs. 4.1.2 Ventilation (when applicable). 4.1.3 Grade slab and/or floor slab. 4.2 Procedures for Inspection - The
Inspector will: 4.2.1 Describe the type of structure
and material comprising the structure and other items inspected. 4.2.2 Observe the condition and
serviceability of visible, exposed areas of foundation walls, grade slab,
bearing walls, posts, piers, beams, joists, trusses, subfloors, chimney
foundations, stairs, and other similar structural components. 4.2.3 Inspect foundations for
indications of flooding, moisture, or water penetration. 4.2.4 Observe subfloor crawl space
ventilation and vapor barriers. 4.2.5 Operate the sump pump when
present. 4.2.6 Inspect the visible and
accessible wooden members. 4.2.7 Observe the visible condition
of floor slab when present. 4.3 Limitations - The Inspector is
not required to: 4.3.1 Enter subfloor crawl spaces
with headroom of less than 3 feet, obstructions, or other detrimental
conditions. 4.3.2 Move stored items or debris or
perform excavation to gain access. 4.3.3 Enter areas which, in the
inspector's opinion, may contain conditions or materials hazardous to the health
and safety of the Inspector. 4.3.4 Operate sump pumps equipped
with internal/water dependent switches. 5. Exterior 5.1 Components for Inspection. 5.1.1 Visible structural components. 5.1.2 Wall covering, trim, and
protective coating. 5.1.3 Windows and doors. 5.1.4 Attached porches, decks, steps,
balconies, handrails, guardrails, carports. 5.1.5 Visible exterior portions of
chimneys. 5.2 Procedures for Inspection - The
Inspector will: 5.2.1 describe type and material
comprising the exterior components inspected. 5.2.2 Observe the condition of the
components from the ground level. 5.2.3 Observe condition of
representative number of visible windows and doors. 5.2.4 Inspect attached porches,
decks, steps, balconies, handrails, and guardrails. 5.3 Limitations - The Inspector is
not required to: 5.3.1 Inspect buildings, decks,
patios, retaining walls, and other structures detached from the house. 5.3.2 Evaluate function of shutters,
awnings, storm doors, storm windows and similar accessories. 5.3.3 Inspect or test the operation
of security locks, devices, or systems. 5.3.4 Evaluate the presence, extent,
and type of insulation and vapor barriers in the exterior walls. 5.3.5 Examine the interior of the
chimney flues or determine the presence or absence of flu liners. 5.3.6 Inspect for safety type glass
or the integrity of thermal window seals or damaged glass. 6. Roof Coverings, Flashings,
Gutters, Downspouts and Roof Ventilation 6.1 Components for Inspection. 6.1.1 Roof covering material. 6.1.2 Rain gutter and downspout
system. 6.1.3 Visible portions of roof
flashings. 6.1.4 Roof ventilation. 6.1.5 Roof soffits and fascias. 6.1.6 Roof skylights and other roof
accessories. 6.2 Procedures for Inspection - The
Inspector will: 6.2.1 Describe the type of roofing
and gutters. 6.2.2 Observe the condition of
visible roof material, rain gutter and downspout systems, visible portions of
roof flashings, roof soffits and fascias, roof vents, skylights and other roof
accessories visible from the exterior. 6.2.3 If possible, inspect the roof
surface and components from arms-length distance or with binoculars from the
ground. 6.2.4 Inspect flat roofs where
internal accessibility is readily and safely available. 6.2.5 Report presence of roof
ventilation. 6.3 Limitations - The Inspector is
not required to: 6.3.1 Walk on or access a roof where
it could damage the roof or roofing material or be unsafe for the Inspector. 6.3.2 Remove snow, ice, debris or
other conditions that prohibit the observation of the roof surfaces. 6.3.3 Inspect internal gutter and
downspout systems and related underground drainage piping. 6.3.4 Inspect antennas, lightning
arresters, or similar attachments. 6.3.5 Operate powered roof
ventilators. 6.3.6 Determine remaining life
expectancy of roof coverings, presence or absence of hail damage; manufacturers'
defects, exceptions, installation methods or recalls; or number of layers. 6.3.7 Determine adequacy of roof
ventilation. 7. Roof Structure, Attic and
Insulation 7.1 Components for Inspection. 7.1.1 Roof framing, sheathing and
decking. 7.1.2 Attic insulation. 7.2 Procedures for Inspection - The
Inspector will: 7.2.1 Describe the type of material
comprising the roof structure in the visible attic area. 7.2.2 Observe the condition of the
visible roof structure and attic components where readily and safely accessible. 7.2.3 Investigate evidence of the
presence of water penetration. 7.2.4 Determine the presence of attic
insulation and its approximate thickness. 7.3 Limitations - The Inspector is
not required to: 7.3.1 Enter attic spaces with
headroom of less than 5 feet, with insulation covering the ceiling joist, or
bottom truss cord, or if there are obstructions, trusses, or other detrimental
conditions, 7.3.2 Break or otherwise damage the
surface finish or weather seal on or around access panels and covers. 8. Attached Garage(s), Carports 8.1 Components for Inspection. 8.1.1 Exterior & interior walls,
ceilings, floors, windows, doors, roof, foundation. 8.1.2 Electrical system and
components. 8.1.3 Plumbing system and components. 8.1.4 Heating systems or units. 8.2 Procedures for Inspection - The
Inspector will: 8.2.1 Describe type and material of
door(s), exterior walls, roof (if applicable), and other items to be inspected.
8.2.2 Observe the condition and
function of listed components; electric, plumbing, heating and similar systems. 8.2.3 Inspect vehicle doors for type,
general condition, and intended function by manual operation or by the use of
permanently affixed opener(s). 8.3 Limitations - The Inspector is
not required to: 8.3.1 Inspect or operate equipment
housed in the garage area except as otherwise addressed in the Standards. 8.3.2 Verify or certify safe
operation of any auto reverse or related safety function(s) of a vehicle door. 9. Electrical 9.1 Components for Inspection. 9.1.1 Entrance of the primary service
from masthead to main panel. 9.1.2 Main and sub-panels including
feeders. 9.1.3 Branch circuits, connected
devices, and lighting fixtures. 9.2 Procedures for Inspection - The
Inspector will: 9.2.1 Describe type and location of
primary service (overhead or underground), voltage, amperage, and over-current
protection devices (fuses or breakers). 9.2.2 Observe existence of a
connected grounding conductor when accessible. 9.2.3 Inspect the main and branch
circuit conductors for proper over current protection and condition by visual
observation after removal of the readily accessible main and sub electric panel
cover(s). 9.2.4 Report presence of aluminum
branch wiring at main and sub-panels. 9.2.5 Verify operation of a
representative number of accessible switches, receptacles and light fixtures. 9.2.6 Verify grounding and polarity
of a representative number of receptacles in proximity to plumbing fixtures or
on the exterior. 9.2.7 Verify operation of ground
fault circuit interrupters (GFCI), if present. 9.2.8 Observe the general condition
of visible branch circuit conductors that may constitute a hazard to the
occupant or the structure by reason of improper use or installation of
electrical components. 9.3 Limitations - The Inspector is
not required to: 9.3.1 Insert any tool, probe or
testing device into the main or sub-panels. 9.3.2 Activate electrical systems or
branch circuits which are not energized. 9.3.3 Operate overload protection
devices. 9.3.4 Inspect ancillary systems,
including but not limited to: burglar alarms, home protection systems, low
voltage relays, smoke/heat detectors, antennas, electrical de-icing tapes, lawn
sprinkler wiring, swimming pool wiring, or any systems controlled by timers. 9.3.5 Move any objects, furniture, or
appliances to gain access to any electrical component. 9.3.6 Test every switch, receptacle,
and fixture. 9.3.7 Remove switch and outlet cover
plates. 9.3.8 Inspect electrical equipment
not readily accessible or dismantle any electrical device or control. 9.3.9 Verify continuity of connected
service ground(s). 10. Plumbing 10.1 Components for Inspection. 10.1.1 Visible water supply lines. 10.1.2 Visible waste/soil and vent
lines. 10.1.3 Fixtures and faucets. 10.1.4 Domestic hot water system and
fuel source. 10.2 Procedures for Inspection - The
Inspector will: 10.2.1 Describe material of the main
line and water supply lines. 10.2.2 Verify the presence of a main
water supply valve. 10.2.3 Describe type of sanitary
waste piping. 10.2.4 Describe type and capacity of
domestic water heating unit(s). 10.2.5 Inspect the condition of
accessible and visible water and waste lines. 10.2.6 Inspect and operate fixtures
and faucets. 10.2.7 Inspect and operate the
domestic hot water system. 10.2.8 Inspect and operate drain
pumps and waste ejector pumps when possible. 10.2.9 Test the water supply for
functional flow. 10.2.10 Test waste lines from sinks,
tubs and showers for functional drainage. 10.3 Limitations - The Inspector is
not required to: 10.3.1 Operate any main, branch or
fixture valve, except faucets, or determine water temperature. 10.3.2 Inspect any system that is
shut-down or secured. 10.3.3 Inspect any plumbing
components not readily accessible. 10.3.4 Inspect any exterior plumbing
components or interior or exterior drain systems. 10.3.5 Inspect interior fire
sprinkler systems. 10.3.6 Evaluate the potability of any
water supply. 10.3.7 Inspect water conditioning
equip. incl. softener and filter systems. 10.3.8 Operate freestanding or
built-in appliances. 10.3.9 Inspect private water supply
systems. 10.3.10 Test shower pans, tub and
shower surrounds, or enclosures for leakage. 10.3.11 Inspect gas supply system for
materials, installation or leakage. 10.3.12 Evaluate the condition and
operation of water wells and related pressure tanks and pumps; the quality or
quantity of water from on-site water supplies; or the condition and operation of
on-site sewage disposal systems such as cesspools, septic tanks, drain fields,
related underground piping, conduit, cisterns, and equipment. 10.3.13 Inspect and operate fixtures
and faucets if the flow end of the faucet is connected to an appliance. 10.3.14 Record location of any
on-site visible fuel tanks within or directly adjacent to structure. 11. Central Heating 11.1 Components for Inspection. 11.1.1 Fuel source. 11.1.2 Heating equipment. 11.1.3 Heating distribution. 11.1.4 Operating controls. 11.1.5 Flue pipes, chimneys and
venting. 11.1.6 Auxiliary heating units. 11.2 Procedures for Inspection - The
Inspector will: 11.2.1 Describe type of fuel, heating
equipment, and heating distribution system. 11.2.2 Operate the system using
normal readily accessible control devices. 11.2.3 Open readily accessible
panels, covers provided by mfg. or installer, if readily detachable. 11.2.4 Observe condition of normally
operated controls & components of systems. 11.2.5 Observe visible flue pipes,
dampers and related components for functional operation. 11.2.6 Observe the condition of a
representative number of heat sources in each habitable space of the house. 11.2.7 Inspect the operation of fixed
supplementary heat units. 11.3 Limitations - The Inspector Is
not required to: 11.3.1 Activate or operate heating or
other systems that do not respond to normal controls or have been shut-down. 11.3.2 To inspect or evaluate a heat
exchanger. 11.3.3 Inspect equipment or remove
covers or panels that are not readily accessible. 11.3.4 Dismantle any equipment,
controls, or gauges. 11.3.5 Inspect the interior of
chimney flues. 11.3.6 Inspect heating system
accessories, such as humidifiers, air purifiers, motorized dampers, heat
reclaimers, etc. 11.3.7 Inspect solar heating systems. 11.3.8 Activate heating, heat pump
systems, or other systems when ambient temperatures or other circumstances are
not conducive to safe operation or may damage the equipment. 11.3.9 Evaluate the type of material
contained in insulation and/or wrapping of pipes, ducts, jackets and boilers. 11.3.10 Operate digital-type
thermostats or controls. 11.3.11 Evaluate capacity, adequacy,
efficiency of a heating or cooling system. 11.3.12 Test or operate gas logs,
built-in gas burning appliances, grills, stoves, space heaters, or solar heating
devices. 11.3.13 Determine clearance to
combustibles or adequacy of combustion air. 12. Central Air Conditioning 12.1 Components for Inspection. 12.1.1 Cooling equipment. 12.1.2 Cooling distribution. 12.1.3 Operating controls. 12.2 Procedures for Inspection - The
Inspector will: 12.2.1 Describe the type of central
air conditioning system and energy sources. 12.2.2 Operate the system using
normal control devices. 12.2.3 Open readily accessible access
panels or covers provided by the manufacturer or installer, if readily
accessible. 12.2.4 Observe the condition of
controls and operative components of the complete system, conditions permitting. 12.2.5 Observe the condition of a
representative number of the central air cooling outlets in each habitable space
of the house. 12.3 Limitations - The Inspector is
not required to: 12.3.1 Activate or operate cooling or
other systems that have been shut-down. 12.3.2 Inspect gas-fired
refrigeration systems, evaporative coolers, or wall or window-mounted air
conditioning units. 12.3.3 Check pressure of system
coolant or determine the presence of leakage. 12.3.4 Evaluate the capacity,
efficiency, or adequacy of the system. 12.3.5 Operate equipment or systems
if exterior temperature is below 60° Fahrenheit or when other circumstances are
not conducive to safe operation or may damage the equipment. 12.3.6 Remove covers or panels that
are not readily accessible. 12.3.7 Dismantle any equipment,
controls, or gauges. 12.3.8 Check the electrical current
drawn by the unit. 12.3.9 Operate digital-type
thermostats or controls. 13. Interior 13.1 Components for Inspection. 13.1.1 Walls, ceilings, floors,
windows, and doors. 13.1.2 Steps, stairways, balconies,
railings. 13.1.3 Fireplaces. 13.1.4 Electric outlets and fixtures. 13.1.5 Plumbing fixtures and
components. 13.1.6 Heating and cooling
distribution. 13.2 Procedures for Inspection - The
Inspector will: 13.2.1 Observe the visible condition
of the surfaces of walls, ceilings, and floors relative to structural integrity
and evidence of water penetration. 13.2.2 Verify the presence of steps,
stairways, balconies, handrails and guardrails and observe their condition. 13.2.3 Describe type, material,
condition and operation of a representative number of windows, doors and their
hardware. 13.2.4 Inspect the exterior condition
of the kitchen cabinets and counter tops. 13.2.5 Observe the condition of
fireplaces, dampers, fire boxes and hearths readily visible. 13.2.6 Locate and observe a
representative number of electrical outlets/fixtures and wiring in each room as
described in Section 9. 13.2.7 Comment on presence or absence
of smoke detectors. 13.2.8 Observe condition and
operation of plumbing fixtures and components in each room as described in
Section 10, 13.3 Limitations - The Inspector is
not required to: 13.3.1 Ignite fires in a fireplace or
stove to determine the adequacy of draft, perform a chimney smoke test, or
inspect any solid fuel device in use. 13.3.2 Evaluate the installation or
adequacy of inserts, wood burning stoves, or other modifications in a fireplace,
stove, or chimney. 13.3.3 Determine clearance to
combustibles in concealed areas. 13.3.4 Determine cosmetic condition
of ceilings, walls, floor coverings, components. 13.3.5 Determine if the bath and/or
kitchen vent fan ducting exhausts air to exterior of house. GLOSSARY OF TERMS Activate: To turn on, supply power,
or enable systems, equipment, or devices to become active by normal control
means. Examples include turning on the gas or water supply valves to the
fixtures and appliances and activating electrical breakers or fuses. Additional Inspection Services: Those
services offered in addition to the home inspection as defined in these
standards, including but not limited to the following examples; wood destroying
insect-organism and environmental testing. Adversely Affect; Constitute, or
potentially constitute, a negative or destructive impact. Appliance: A household device
operated by use of electricity or gas. Not included in this definition are
components covered under central heating, central cooling, or plumbing. Describe: To distinguish from another
system or component. Detrimental Conditions: Any
conditions that, in the opinion of the inspector, may likely be unsafe,
unhealthy, or in any way harmful to the inspector or to components of the
property. Evaluate: To ascertain, judge, or
form an opinion about an item or condition. Foundation: The base upon which the
structure or a wall rests; usually masonry, concrete, or stone, and generally
partially underground. Function: The action for which an
item, component or system is specially fitted or used or for which an item,
component or system exists; to be in action or perform a task. Functional: Performing, or able to
perform, a function. Functional Drainage: A drain is
functional when it empties in a reasonable amount of time and is not subject to
overflow when one supply faucets is left on. Functional Flow: Sufficient water
flow to provide uninterrupted supply to the highest, unrestricted tap (faucet
furthest from the source) when a single intermediate, unrestricted tap is
operated simultaneously with uninterrupted flow. Habitable: In a condition suitable
for human habitation. Habitable Spaces: Rooms or spaces
used for sitting, sleeping, bathing, toilets, eating or cooking. Not considered
habitable spaces by these Standards are closets, halls, storage spaces and
utility areas. Heat Source: A heat source may be a
radiator, convector unit, radiant panel, heat pipe, ductwork, grille, register,
or other device(s) from which heat is intended to be emitted. Home Inspection: The process by which
an inspector visually examines the readily accessible systems and components of
a home and operates those systems and components utilizing the Standards of
Practice as a guideline. Inspect: To evaluate carefully
without use of technically exhaustive methods. Inspected Property: The readily
accessible areas of the buildings, site, items, components, and systems included
in the inspection. Intended Function: Performing or able
to perform the usual function for which an item is designed, or fitted; and be
in a condition (state of repair) appropriate to this function, its age and
location. [See Function] Observe: To see through visual
directed attention. Operate: To cause equipment or
systems that have been activated to perform their intended function(s), such as
turning on a water faucet or turning up the thermostat on an activated heating
system. Readily Accessible: An item or
component is readily accessible if, in the judgment of the inspector, it is
capable of being safely observed without movement of obstacles, detachment or
disengagement of connecting or securing devices, or other unsafe or difficult
procedures to gain access. Representative Number: A sufficient
number to serve as a typical or characteristic example of the item(s) inspected. Shut-down: A system or equipment is
considered to be shut-down when its normal control device(s) will not cause it
to become activated or operational. The Inspector is not required to activate or
operate safety devices (fuses, breakers, etc.) in the "off" position. It is not
the responsibility of the Inspector to put these controls in the "on" mode, nor
to ensure that the equipment or systems to be tested are operable at the time of
the inspection. Slab on Grade: Structures that have
no crawl space and are in direct contact with the soil. Slabs may or may not
have supporting piers or pads. Technically exhaustive: An inspection
is technically exhaustive when it involves the use of measurements, instruments,
testing calculations and other means to develop scientific or engineering
findings, conclusions, and recommendations. Verify: To confirm or substantiate. CODE OF ETHICS To maintain the integrity and high
standards of skill and practice in the home inspection profession, the following
rules of conduct and ethics shall be binding upon the use of the Standards of
Practice (Standards) of the National Association of Home Inspectors, Inc.
(NAHI): 1. Inspector will act as a
disinterested third party & will discharge his duties with integrity and
fidelity to the public, with fairness & impartiality to all parties. 2. Inspector shall uphold honor &
dignity of this profession & avoid association w/any enterprise of questionable
character or apparent conflict of interest. 3. The Inspector will express an
opinion only when it is based on practical experience and honest conviction. 4. The Inspector will always act in
good faith toward the client. 5. The Inspector will not disclose
any information concerning the results of the inspection without the approval of
the client for whom the inspection was performed. 6. The Inspector will not accept
compensation, financial or otherwise, from more than one interested party for
the same service on the same property without the consent of all interested
parties. 7. The Inspector will not accept nor
offer commissions or allowances, directly or indirectly, from other parties
dealing with the client in connection with work that may be responsible as a
result of the home inspection report as defined by the NAHI Standards of
Practice. 8. The Inspector may provide
"additional inspection services" only after proper disclosure to the client that
the "additional inspection services" are not part of the home inspection, as
defined by the NAHI Standards of Practice. In addition, the sale of products or
correction of deficiencies are not permitted under this Code of Ethics. The
Inspector will promptly disclose to the client any interest in any business
which may affect the client, the quality or the result of the inspection. 9. The Inspector shall make every
effort to uphold, maintain and improve the professional practice, integrity and
reputation of NAHI. He will report all violations of this Code by other members,
and any other relevant information, to NAHI for possible remedial action. 10. An appraisal or opinion of the
market value of the inspected property will not be expressed by the Inspector
within the context of the inspection. 11. Use of the NAHI logo and name is
limited to those persons holding the designation of Regular Member. Associate,
NAHI CRI, and Affiliate Members may use specifically designated logos in
advertising.
Welcome to
A1-HomeInspection.com®
The NAHI Standards of Conduct & Code of Ethics